Mercury INSTALLATION MANUAL D7.3L D-TRONIC Manual de usuario Pagina 31

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 90
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 30
D7.3L D-TRONIC DIESEL ENGINES - BRAVO MODELS
Page 31 of 90
Power Trim Pump
1. Mount pump in desired location.
IMPORTANT: Make hydraulic connections as quickly as possible to prevent oil from
leaking out of system. Be careful not to cross-thread or overtighten hose fittings.
75126
50630
75127
50632
a
c
d
e
f
g
b
a-Black Hose (UP Circuit)
b-Gray Hose (DOWN Circuit)
c-Harness Connector
d-Clamp
e-Trim Limit Switch Wire (with Blue Sleeve) - to BLUE/WHITE Harness Wire
f-Trim Limit Switch Wire (with Purple Sleeve) to PURPLE/WHITE Harness Wire
g-Wire Retainer and Sta-Strap
2. Connect hydraulic hoses to trim pump. Torque fittings to 100-150 lb-in. (11-16 Nm).
3. Connect power trim pump control harness to trim pump. Secure with clamp.
4. Connect trim limit switch wires and secure with wire retainer and sta-strap.
Vista de pagina 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 89 90

Comentarios a estos manuales

Sin comentarios