Mercury XR2 Manual de instalación Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 21
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
- 17 -
6. Secure powerhead to drive housing cover with
eight (8) M10 x1.5 nuts. Torque fasteners to 47
Nm (35 lb ft) following the torque sequence given.
Repeat torque sequence to ensure all fasteners
retain their torque.
TOP VIEW


3
7
5
1
2
4
8
6
28242
28237
a
a
a - M10 x 1.5 Nuts – Torque to 47 Nm (35 lb ft)
7. Connect fuel line to fuel inlet fitting, secure with
U.S. Coast Guard approved hose clamp
(183.532).
b
55087
b - Fuel Inlet Fitting
Battery Connection
NOTE: Engine electrical system is negative (–)
ground.
1. Connect positive (+) battery cable (usually red) to
starter solenoid using protective boot (provided).
2. Connect negative (–) battery cable (usually black)
to engine ground at forward starter motor bolt.
!
WARNING
U.S. Coast Guard regulation #33 CFR 183.445 re-
quires that the positive battery cable connection
at the starter solenoid terminal be protected by ei-
ther a boot (“b” shown following), or protective
shield.
a
b
28238
a - Positive Battery Cable Attaching Location
b - Boot Protector for Positive Battery Cable
c
28237
c - Forward Starter Bolt (Engine Ground)
3. Connect battery cables to battery. Make sure that
all battery terminal connections are tight; then,
spray terminals with a battery connection sealant
to help prevent corrosion.
Vista de pagina 16
1 2 ... 12 13 14 15 16 17 18 19 20 21

Comentarios a estos manuales