STORAGE
136 eng
3. Pull the drain hose off the right side fitting. Hold the open
end of the hose over a container.
4. Loosen drain screw and drain the fuel filter chamber.
a - Drain screw
b - Drain hose
c - Right side fitting
5. Retighten the drain screw and reattach the hose.
6. Pull the drain hose off the left side fitting. Hold the open end
of the hose over a container.
7. Loosen the drain screw and drain the float chamber.
a - Left side fitting
b - Drain screw
c - Drain hose
8. Retighten the drain screw and reattach the hose.
9. Premix the following in a container:
a. 8 cc (0.27 oz.) or 2 teaspoons of Mercury Precision
Quickleen lubricant.
b. 8 cc (0.27 oz.) or 2 teaspoons of Mercury Precision Fuel
Stabilizer.
a
b
c
23751
a
b
c
23752