OUTBOARD INSTALLATION
108 eng
FUEL DEMAND VALVE (FDV) REQUIREMENT
Whenever a pressurized fuel tank is used, a fuel demand valve
is required to be installed in the fuel hose between the fuel tank
and primer bulb. The fuel demand valve prevents pressurized
fuel from entering the engine and causing a fuel system overflow
or possible fuel spillage.
The fuel demand valve has a manual release. The manual
release can be used (pushed in) to open (bypass) the valve in
case of a fuel blockage in the valve.
a - Fuel demand valve ‑ installed
in the fuel hose between the
fuel tank and primer bulb
b - Manual release
c - Vent/water drain holes
FUEL TANKS
Portable Fuel Tank
Select a suitable location in the boat within the engine fuel line
length limitations and secure the tank in place.
Permanent Fuel Tank
Permanent fuel tanks should be installed in accordance with
industry and federal safety standards, which include
recommendations applicable to grounding, anti‑siphon
protection, ventilation, etc.
FILLING THE FUEL SYSTEM
For the initial start of a new engine, or for an engine that ran out
of fuel or was drained of fuel, the fuel system should be filled as
follows:
1. Squeeze the fuel line primer bulb until it feels firm.
2. Turn the ignition key switch to the "ON" position for three
seconds. This operates the electric fuel pump.