STORAGE
SECTION 6
Page 134 CMD-4081850 / 90-860094030 SEPTEMBER 2003
CD928 w / changes
Recommissioning
NOTICE
Refer to Cold Weather Extended Storage - Precautions, BEFORE proceeding.
1. Reinstall seawater pump components as follows:
a. Place impeller in pump housing, turning clockwise while simultaneously pushing
firmly inward onto pump shaft.
NOTE: Use new gasket. Install in correct position - wide surface on side of cam.
b. Install pump cover with new gasket in noted position.
c. Install the seawater pump cover mounting screws. Tighten securely.
NOTE: Pump shown removed for visual clarity only.
71366
a
b
c
d
e
a
a-Impeller
b-Seawater Pump Housing
c-Gasket (Wide Surface On Cam Side)
d-Cover
e-Cover Screws