MAINTENANCE
SECTION 5
Page 80 CMD-4081850 / 90-860094030 SEPTEMBER 2003
00000 was CD919
D4.2L LD
1. Start engine and allow it to warm up to normal operating temperature.
2. Stop engine and allow some time for oil to drain into oil pan (approximately 5 minutes).
3. Remove fitting from end of crankcase oil pump. Attach a suitable hose for draining.
4. Pump oil out of crankcase into drain pan. When crankcase is empty, remove hose and
reinstall crankcase oil pump fitting. Tighten securely.
76379
a
b
a-Threaded fitting
b-Crankcase oil pump
5. Remove and discard oil filter and sealing ring. Coat sealing ring on new filter with oil and
install filter. Hand tighten only, do not use a filter wrench.
a
75297
a-Oil filter
6. Remove oil fill cap and refill engine with new oil. Refer to Filling.
IMPORTANT: When refilling engine with oil always use dipstick to determine how
much oil is required.
IMPORTANT: On all engines except EDI (D-Tronic) models: After oil change, pre-lubri-
cate turbocharger and engine. To do this, engage the stop switch and hold while you
turn the key switch to START position. Doing this TOGETHER turns the engine with-
out starting it. Do not engage starter for more than 15 seconds; allow at least one min-
ute cool down time before re-engaging starter for another 15 seconds. Ensure that
the starter does not overheat.
7. Start the engine and check for leaks.