CA825
Flushing Cooling System
CA801
3.0L Single Point Drain
If engine is operated in salty or brackish water, flush cooling system
(preferably after each use) to reduce corrosion and prevent the
accumulation of deposits in the system. Thoroughly flush cooling
system prior to storage.
IMPORTANT: Do NOT start or operate engine at any point in this
procedure.
CAUTION
Do not operate engine with blue drain hoses disconnected.
Hot water can discharge violently.
1 Push quick connect fitting release button on engine block blue
drain hose and remove blue drain hose from bracket.
2 Ensure engine block blue drain hose is in correct position below
its connection point to the block.
3 Attach the female end of the water hose adapter fitting to a water
supply.
4 Attach the engine block blue drain hose to the male end on the
water hose adapter fitting.