Electrical System Overload Protection
If an electrical overload occurs, a fuse will blow or the circuit breaker
will trip open. The cause must be found and corrected before
replacing fuse or resetting circuit breaker.
1 A circuit breaker provides protection for engine wiring harness
and instrumentation power lead. Reset by pushing RESET button IN.
A Carburetor Models
B EFI Models Except 7.4L MPI
C 7.4L MPI
NOTE: In an emergency, when engine must be operated and cause
for high current draw cannot be located and corrected, turn OFF or
disconnect all accessories connected to engine and instrumentation
wiring. Reset circuit breaker. If breaker remains open, electrical over-
load has not been eliminated. Further checks must be made on elec-
trical system.
2 A 90 Amp fuse is located on the large post of the starter solenoid.
This fuse is designed to protect the engine wiring harness if an elec-
trical overload occurs.
3 On EFI Models: Three fuses are located on the port side of the
engine. These fuses control various EFI circuits.
A Fuel Pump Fuse - 15 Amp
B ECM / Injector Fuse - 10 Amp
C ECM / Battery Fuse - 15 Amp